Onicon System-10 Dualnet Bedienungsanleitung Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
System-10 Dual Network Interface Installation Guide 05/14 - 0972-1 Page 17
1500 North Belcher Road, Clearwater, Florida 33765 Tel (727) 447-6140 Fax (727) 442-5699-
www.onicon.com [email protected]
0526
7-6-07
SYSTEM-10 BTU Meter BACnet/IP Driver
Protocol Implementation Conformance Statement (PICS)
BACnet Protocol
Date: July 6, 2007
Vendor Name: ONICON Incorporated
Product Name: System-10 Btu Meter
Product Model: SYSTEM-10-BAC-IP
BACnet Standardized Device Profile (Annex L)::
BACnet Smart Sensor (B-SS)
BACnet Smart Actuator (B-SA)
BACnet Application Specific Controller (B-ASC)
BACnet Interoperability Building Blocks Supported (Annex K):
K.1.2 BIBB Data Sharing ReadProperty B (DS-RP-B)
K.1.8 BIBB Data Sharing WriteProperty B (DS-WP- B)
K.5.2 BIBB Device Management Dynamic Device
Binding-B (DM-DDB-B)
Segmentation Capability:
None
Standard Object Types Supported:
Device Object Multi State Input Output
Analog Input Multi State Output
Analog Output Multi State Value
Analog Value
Binary Input
Binary Output
Binary Value
For all these properties the following apply:
1. Does not support BACnet CreatObject
2. Does not support BACnet DeleteObject
3. Does not support any optional properties
4. No additional writeable properties exist
5. No proprietary properties exist
6. No range restrictions exist
Data Link Layer Options:
BACnet IP (Annex J)
Networking Options:
BACnet/IP Broadcast Management Device (BBMD)
Does the BBMD support regi
strations by Foreign
Devices? Yes
Device Address Binding:
Not supported
Character Sets Supported:
ANSI X3.4.
Product Description: The System-10 BTU Meter provides highly accurate thermal energy measurement in chilled water, hot water and
condenser water systems based on signal inputs from two matched temperature sensors (included) and any of ONICON's insertion or inline flow
meters (ordered separately). The System-10-BAC provides energy, flow and temperature data on a local alphanumeric display and to the network
via the BACnet/IP communications driver. An optional auxiliary input is also available to totalize pulses from another device and communicate the
total directly to the network.