2.2 F-2600 SERIES IN-LINE FLOW METER INSTALLATION
Install the in-line ow meter between two conventional pipe anges as shown in Figures 6 and
7. Table 1 provides the recommended minimum stud bolt lengths for wafer-style meter body size
and different ange ratings.
The meter's inside diameter is equal to the same size nominal pipe ID in schedule 80. For
example, a 2” meter has an ID of 1.939” (2” schedule 80). Do not install the meter in a pipe with
an inside diameter smaller than the inside diameter of the meter. For schedule 160 and higher
pipe, a special meter is required. Consult the factory before purchasing the meter.
In-line meters require customer-supplied gaskets. When selecting gasket material, make sure that
it is compatible with the process uid and pressure ratings of the specic installation. Verify that
the inside diameter of the gasket is larger than the inside diameter of the ow meter and adjacent
piping. If the gasket material extends into the ow stream, it will disturb the ow and cause
inaccurate measurements.
Flange Bolt Specications
Stud Bolt Lengths for Each Flange Rating (inches)
Line Size
Class 150
and PN16
Class 300
and PN40
Class 600
and PN64
1 " 6.00 7.00 7.50
1½ " 6.25 8.50 9.00
2 " 8.50 8.75 9.50
3 " 9.00 10.00 10.50
4 " 9.50 10.75 12.25
Table 1. Minimum Recommended Stud Bolt Lengths for Wafer Meters
The required bolt load for sealing the gasket joint is affected by several application-dependent
factors; therefore, the required torque for each application may be different. Refer to the ASME
Pressure Vessel Code guidelines for bolt tightening standards.
Figure 5. Flange Bolt Tightening Sequence